简介:摘要:目的 总结消毒供应室应用碱性洗涤剂对护理清洁质量的影响。方法: 2019年 11月起使用至 2020年 5月,以我院消毒供应室设备管理为例进行总结分析。选择消毒供应室清洗的 2000台医疗器械进行清洗质量比较。实验组用碱性洗涤剂清洗,常规组用 rukov多酶洗涤剂清洗。总结医疗器械相关交叉感染发生率及工艺改进前后的清洗合格率。结果实验组感染事件数和清洗合格率均显著高于常规组,差异有显著性( P<0.05)。结论:消毒供应室应用碱性洗涤剂对护理清洁质量有显著影响。干血迹和变性蛋白的清洗能力更为突出,成本低,安全性好,实用性强。值得临床推广。
简介:摘要目的探索生物膜清洗剂与2种多酶清洗剂在内镜生物膜清除效果上的差异。方法建立铜绿假单胞菌内镜生物膜模型,对照组采用灭菌水浸泡,实验组分别采用1号多酶清洗剂、2号多酶清洗剂及生物膜清洗剂进行浸泡。在室温下分别作用5、10、15 min后,以细菌活菌计数法及扫描电镜法评价不同清洗剂对内镜生物膜模型的清洗效果。各组间活菌计数比较采用方差分析。结果作用5、10、15 min后,测定的生物膜菌落计数(CFU/cm2)空白对照组为7.92±0.21,1号多酶清洗剂组分别为5.31±0.10、5.04±0.08、4.90±0.16,2号多酶清洗剂组分别为5.53±0.30、5.39±0.21、5.03±0.42,生物膜清洗剂组分别为3.53±0.30、3.01±0.07、2.82±0.26。在相同作用时间下,两种多酶清洗剂组的菌落计数比较差异无统计学意义(P>0.05),生物膜清洗剂组菌落计数少于两种多酶清洗剂组(P<0.05)。且随着浸泡时间增加,生物膜清洗剂组菌落计数逐渐减少(P<0.05)。作用15 min后,扫描电镜下见生物膜清洗剂组清洗后的生物膜及细菌残留最少。结论两种多酶清洗剂的清洗效果相当,生物膜清洗剂较多酶清洗剂对内镜生物膜的清除效果更好,可明显提高内镜清洗质量。
简介:摘要目的在白喉-破伤风-无细胞百日咳疫苗生产车间玻璃瓶清洗剂的变更中,引入质量风险管理,对新清洗剂进行风险分析与评估,以确保更换清洗剂对产品质量无影响。方法运用风险评估工具对新清洗剂进行风险评估,根据风险级别制定相应风险控制措施,对新清洗剂进行验证,确认其清洗效果以及对产品的影响。结果清洗后玻璃瓶淋洗水中细菌内毒素含量≤0.25内毒素单位/ml、总好氧微生物计数≤100菌落形成单位/ml、总霉菌酵母菌计数≤10菌落形成单位/ml、总有机碳≤1.5 μg/cm2(淋洗水和擦拭取样)、电导率≤1.3 μS/cm,结果均符合要求。结论在变更控制中运用质量风险管理,指导变更控制措施的制定和变更内容的实施,保证了更新新清洗剂的风险可接受,且产品质量不受变更影响。
简介:摘要:目的:研究碱性清洗剂对消毒供应中心护理清洗质量的提升效果 。 方法:选择位于 2019 年 2 月到 2020 年 2 月期间 需要清洗的医疗器具 400 件,随机自其中抽取 200 件设为对照组,另 200 设为观察组,对照组使用多酶清洗剂,观察组使用碱性清洗剂,对比两组清洗质量、清洗实用性 。 结果:观察 组清洗优良率显著高于对照组 , 观察组清洗安全性、实用性和经济性评分均高于对照组, P < 0.05 。 结论:消毒供应中心使用 碱性清洗剂对医疗器械进行清洗,可以有效提升血渍以及变性蛋白质的清洗效率,使用成本较低,安全性高,整体使用效果好。
简介:摘要目的探讨3种眼科显微器械清洗方法的清洗剂残留情况、清洗质量和清洗效率。方法收集南京医科大学第一附属医院2018年3月污染的眼科显微器械12 000件,采用区组随机化法将其均分为A、B、C组,每组4 000件器械。A组选取减压沸腾式清洗,B组选取全自动清洗消毒器清洗,C组选取手工加超声清洗机清洗。采用目测法及带光源的放大镜检查、ATP生物荧光法测试评价清洗效果;清洗剂残留通过检测清洗前后纯水中电导率变化进行监测,同时记录3组器械处理所需时间用于清洗效率的评价。结果电导率测试结果表明3组清洗方法均无清洗剂残留。ATP检测法和目测法检测清洗合格率比较结果显示,A组的合格率分别为100.00%和99.88%,B组分别为100.00%和99.80%,C组分别为95.00%和97.80%,A组和B组的清洗质量及清洗合格率比较,差异无统计学意义(P>0.05),但均高于C组(P<0.01)。清洗效率比较结果显示,A组每500件器械耗时(86.04±6.60)min,B组为(147.36±14.60)min,C组为(241.50±22.41)min。A组耗时短于B、C组,B组耗时短于C组,差异均有统计学意义(P<0.01)。结论3种清洗方法均无清洗剂残留,但采用减压沸腾式清洗和全自动清洗消毒器清洗可以有效保证清洗质量。与此同时,减压沸腾式清洗相比于全自动清洗消毒器清洗耗时更短,效率更高。
简介: 【摘 要】目的:此次研究分析在消毒供应室医疗器械清洗过程中采用碱性清洗剂对清洗质量的影响。方法:本次研究样本从本院消毒供应室选取 200件医疗器械,研究时间从 2017年 2月开始,截至 2019年 2月,将 2017年 2月 -2018年 2月间采用多醇清洗剂清洗的 100件医疗器械作为对照组,将 2018年 3月 -2019年 2月间采用碱性清洗剂的 100件医疗器械作为实验组,对比两组清洗质量。结果:统计数据分析两组医疗器械清洗质量评分,研究得知,实验组医疗器械清洗质量评分较高,两组对比符合统计学标准( P<0.05)。结论:通过此次研究得知,在消毒供应室医疗器械清洗过程中采用碱性清洗剂,能明显对其清洗质量进行改善,经济成本也比较低。 【关键词】消毒供应室 ;医疗器械 ;碱性清洗剂 ;清洗质量 [Abstract] Objective: to analyze the effect of alkaline detergent on the cleaning quality of medical devices in disinfection supply room. Methods: 200 medical devices were selected from the disinfection supply room of our hospital. The study started in February 2017 and ended in February 2019. 100 medical devices cleaned with polyol detergent from February 2017 to February 2018 were used as the control group, and 100 medical devices cleaned with alkaline detergent from March 2018 to February 2019 were used as the experimental group to compare the cleaning quality of the two groups. Results: statistical data analysis of the two groups of medical device cleaning quality score, the study found that the experimental group of medical device cleaning quality score is higher, the two groups compared with the statistical standard (P < 0.05). Conclusion: through this study, we know that alkaline detergent can improve the cleaning quality of medical devices in disinfection supply room, and the economic cost is relatively low.
简介:摘要: 目的 : 观察 真空 清洗机清洗金属套管的效果,寻求一种高效、安全的金属气管套管的清洗方法。 方法 : 将 200件金属套管随机分为两组,对照组采用手工 + 超声 清洗机清洗,试验组采用 真空 清洗机清洗,使用肉眼 +带光源放大镜进行目测、残留蛋白定量法进行清洁度检查,比较两组器械的清洗效果 ;结果 : 试验组和对照组清洗质量检测,使用带光源的放大镜目测法合格率分别为 100 % 和 86 % ; 残余蛋白定量测定法合格率分别为 98 % 和 82 % ;差异均有统计学意义( P< 0.05)。 结论 : 真空 清洗机清洗金属气管套管效果优于手工 + 超声 清洗机清洗,不仅缩短了清洗时间,提高了清洗质量,预防和降低了院内感染的发生;同时降低了工作人员发生职业暴露的风险。值得在临床上推广使用。
简介:摘要:目的 分析基于清洗前不同预清洗方法对软式内镜清洗消毒效果的改变。方法 自我院2019年3月-2019年9月选择98条需清洗消毒的软式内镜,根据不同的预清洗方法均分为2组,分别采用常规清洗流程与简化清洗流程,对其清洗消毒效果的改变进行分析。结果 常态组消毒流程的时间多于科研组,成本低于科研组,消毒合格率63.27%低于科研组的消毒合格率97.96%,P<0.05,组间差异存在统计学意义。两组软式内镜的血液残留检测结果相近,P>0.05,组间差异无统计学意义;而常态组蛋白残留检测结果明显高于科研组,P<0.05,组间差异存在统计学意义。结论 简化清洗流程的方式相比常规清洗流程对软式内镜清洗消毒效果明显提升,可推广应用。
简介:摘要:目的:去污区是清洗器械的重要区域,在去污区合理规范清洗器械有利于降低交叉感染的几率,提升器械清洁程度。方法:结合临床清洗经验了解器械的重要性以及清洗区对其的影响。结论:经过多方面方法的探讨得出在去污区合理规范的清洗流程会提高器械的洁净程度。
简介:摘要目的研究机械热力清洗频率对于牙科手机损耗以及清洗效果的影响。方法纳入180支可机械热力清洗的全新高速牙科手机,随机分为A、B、C 3组,每组60支。每次使用后,采用专用注油机进行清洗注油,包装灭菌。A、B、C组分别每周、每2周和每3周采用一次机械热力清洗后专用注油机清洗注油,包装灭菌的流程。在3、6、9个月时分别从每组随机抽取5支进行部件可视污渍情况检查,监测清洗效果。结果A、B、C 3组手机平均使用次数为A组(56.60±24.77)次,B组(49.70±30.08)次,C组(46.73±35.16)次,使用次数比较差异无统计学意义(P=0.800);9个月中15支手机出现故障,其中A组4支,B组7支,C组4支,3组比较差异无统计学意义(P=0.660);12支简单维修后继续使用,A组1支,B组7支,C组4支,3组比较差异无统计学意义(P=0.100);3支更换轴芯后继续使用,均为A组。3组清洁程度合格率均为100%。结论牙科手机在专用注油机清洗注油基础上每3周采用一次机械热力清洗能保障其内部清洁,并不会增加损耗,可提高工作效率。
简介:摘要:内蒙古中煤蒙大新能源化工有限公司(以下简称:中煤蒙大)为提高甲醇制烯烃(以下简称: DMTO)的长周期运行。中煤蒙大公司自 2016年 4月 15日原始开工的那天起,一致致力于解决 DMTO装置急冷塔悬浮高,急冷塔无法长周期运行。通过 DMTO装置急冷水过滤器改造,降低急冷水系统中的悬浮物,实现急冷塔和 DMTO装置的长周期稳定运行
简介:
简介:【摘要】目的 研究超声震荡加酶清洗法对于提高管腔吸引器清洗合格率的作用和意义。方法:将2018年2月至2020年1月使用过的同等污染程度的管腔吸引器