Thermal Dissipation Modelling and Design of ITER PF Converter Alternating Current Busbar

(整期优先)网络出版时间:2016-10-20
/ 1
Becausethelargermetallicsurroundsareheatedbytheeddycurrent,whichisgeneratedbytheACcurrentflowingthroughtheACbusbarintheInternationalThermonuclearExperimentalReactor(ITER)poloidalfield(PF)convertersystem,shieldingoftheACbusbarisrequiredtodecreasethetemperatureriseofthesurroundstosatisfythedesignrequirement.ThreespecialtypesofACbusbarwithnaturalcooling,aircoolingandwatercoolingbusbarstructurehavebeenproposedandinvestigatedinthispaper.Foreachcoolingscheme,a3Dfinitemodelbasedontheproposedstructurehasbeendevelopedtoperformtheelectromagneticandthermalanalysistopredicttheiroperationbehavior.Comparingtheanalysisresultsofthethreedifferentcoolingpatterns,watercoolinghasmoreadvantagesthantheotherpatternsanditisselectedtobethethermaldissipationpatternfortheACbusbarofITERPFconverterunit.TheapproachtoqualifythesuitablecoolingschemeinthispapercanbeprovidedasareferenceonthethermaldissipationdesignofACbusbarintheconvertersystem.