学科分类
/ 1
3 个结果
  • 简介:AIM:Tomeasurecentralcornealthickness(CCT)andpre-cornealtearfilmthicknessusingtheGalileidualScheimpfluganalyzer(GSA)inNewZealandWhiterabbits.METHODS:TennormalNewZealandWhiterabbits(20eyes)wereincludedinthisstudy.Withtheassistanceof0.1%fluorescein,thepre-cornealtearfilmcanbewellvisualized.BotheyesofeachrabbitwerescannedoncewiththeGSApre-andpost-instillationof1μL0.1%fluorescein.ThedifferencebetweenthetwomeasurementsofCCT(4-mmdiameter)wasrecordedasthepachymetricvaluesofthecentraltearfilm.RESULTS:TheCCTofpre-andpost-instillationwas388.8±9.5μmand407.0±10.5μm,respectively.Afterapairedt-testanalysis,thecentralpre-cornealtearfilmthicknessof4mmdiameterwas18.2±5.31μmwitha95%confidenceintervalof(15.7,20.6)μm(P<0.001).CONCLUSION:GSAcanbeusedtomeasureCCTandanalyzecentraltearfilmthicknessofrabbitswiththehelpoffluorescein.

  • 标签: TEAR film SCHEIMPFLUG rabbits central CORNEAL
  • 简介:目的:探讨激光周边虹膜成形术(laserperipheraliridoplasty,LPIP)治疗急性闭角型青光眼(acuteangle-closureglaucoma,AACG)急性发作期药物不能控制的高眼压持续状态中的疗效。方法:原发性急性闭角型青光眼67例69眼发作期药物治疗3~6h后眼压仍〉30mmHg时,行LPIP治疗。监测术前和术后30,60min和2h眼压、视力变化。应用UBM测量术前、术后2h房角宽度和虹膜厚度,并应用房角镜观察前房角粘连情况。结果:LPIP后2h,房角开放距离(AOD)较术前明显增大(P〈0.01),小梁虹膜夹角(TIA)增宽、部分患者周边虹膜前粘连(PAS)减少、周边虹膜变薄。所有患者眼压在激光虹膜成形术后不同时间均有不同程度下降。术前平均眼压53.81±10.22mmHg,术后30min平均眼压33.81±9.22mmHg,术后60min为21.93±7.19mmHg,2h后眼压下降至15.16±3.07mmHg,治疗前后差异有显著统计学意义(F=151.79,P〈0.01)。同时所有患者视力都有所提高。结论:LPIP可以明显加深患者的周边前房,增宽房角入口,降低患者眼压,是治疗AACG急性发作期药物不能控制高眼压持续状态的重要辅助措施,为青光眼的进一步治疗创造了条件,并且能够改善预后。

  • 标签: 急性闭角型青光眼 激光虹膜成形术 高眼压持续 状态
  • 简介:AIM:Toevaluatetheaccuracyofsphericalequivalent(SE)estimatesofadouble-passsystemandtocompareitwithretinoscopy,subjectiverefractionandatablemountedautorefractor.METHODS:Non-cycloplegicrefractionwasperformedon125eyesof65healthyadults(age23.5±3.0years)fromOctober2010toJanuary2011usingretinoscopy,subjectiverefraction,autorefraction(AutokeratorefractometerTOPCONKR-8100,Japan)andadoublepasssystem(OpticalQualityAnalysisSystem,OQAS,VisiometricsS.L.,Spain).Nineconsecutivemeasurementswiththedouble-passsystemwereperformedonasubgroupof22eyestoassessrepeatability.ToevaluatethetruenessoftheOQASinstrument,theSElaboratorybiasbetweenthedoublepasssystemandtheothertechniqueswascalculated.RESULTS:TheSEmeancoefficientofrepeatabilityobtainedwas0.22D.SignificantcorrelationscouldbeestablishedbetweentheOQASandtheSEobtainedwithretinoscopy(r=0.956,P<0.001),subjectiverefraction(r=0.955,P<0.001)andautorefraction(r=0.957,P<0.001).ThedifferencesinSEbetweenthedouble-passsystemandtheothertechniquesweresignificant(P<0.001),butlackedclinicalrelevanceexceptforretinoscopy;Retinoscopygavemorehyperopicvaluesthanthedouble-passsystem-0.51±0.50Daswellasthesubjectiverefraction-0.23±0.50D;Moremyopicvalueswereachievedbymeansofautorefraction0.24±0.49D.CONCLUSION:Thedouble-passsystemprovidesaccurateandreliableestimatesoftheSEthatcanbeusedforclinicalstudies.Thistechniquecandeterminethecorrectfocuspositiontoassesstheocularopticalquality.However,ithasarelativelysmallmeasuringrangeincomparisonwithautorefractors(-8.00to+5.00D),andrequirespriorinformationontherefractivestateofthepatient.

  • 标签: DOUBLE-PASS system optical quality RETINOSCOPY autorefraction